KPM13x - ANALOGUE GUARD / CONTROLLER
- Comprises a wide variety of instrumentation for protection,
control and regulation of DC electrical parameters or physical
parameters
- DC Voltage or Current Guards and Controllers
- DC Signal Slave Controllers
- Analogue Signal Controllers
- Triple relay for more flexibility
- One fast response analogue output (<50mS), F-versions
Application
The KPM13x is a digitally controlled guard/controller for use in a large
range of applications such as power guards, load controller, DC current
guards, DC voltage guards, etc.
As an analogue controller it can be
used to monitor a large range of physical parameters as flow, pressure,
temperature, length, weight and more.
An AC or DC auxiliary voltage is required for the unit. A green LED
indicates POWER on. Start of monitoring function is delayed when power
is switched on (default 2 secs delay). In this way false tripping during
power up is avoided.
The precision DIN96 moving coil meter reads the monitored parameter, and has low-reflection glass to ease reading at a distance.
The triple-zone status LEDs at a glance gives the clear safety message, typically LOW TRIP / NORMAL / HIGH TRIP etc.
The standard version has no analogue output. The optional
F-version has an isolated
analogue output signal proportional to meter deflection.
The units three C/O relay outputs may typically be configured for Low,
Low-Low or Negative Trip, High, High-High or Positive Trip and Trip
Status (R3).
The trip levels and trip delays are user settable on unit
rear to suit most applications. (See individual description for relay
operation)
Red relay trip lamps flash instantly (approx. 1 flash per second) when
the trip level is passed, the relay trips after elapsed delay. The lamp
changes state and the trip relay operates after the pre-set delay. If a
trip condition ends during the delay interval, the timer will
automatically reset.
As standard the unit is supplied for automatic reset. Manual reset (latching relays) is optional (All G-versions).
The unit meets EN 61010-1 Cat. III, Pollution degree 2 and the relevant
environmental and EMC tests specified in EN 61326-2-4 to comply with the
requirements of the major Classification Societies.
Voltage Guards
KPM13V15E - KPM13V15F & KPM13V15GE - KPM13V15GF
DC Over and Under Voltage Guard
A DC voltage guard with direct input up to 400VDC. Input from
voltage divider with grounded negative for any voltage range. The unit
is used for protection of any DC motor or mains.
KPM13V16E - KPM13V16F & KPM13V16GE - KPM13V16GF
DC Bi-Polar Voltage Guard
A DC voltage guard with direct input up to +/- 400VDC. Input from
voltage divider with grounded negative for any voltage range. The unit
is used for protection of any DC motor or mains.
Current Guards
KPM13C121E - KPM13C121F & KPM13C121GE - KPM13C121GF
DC Over and Under Current Guard
Direct input up to 1ADC, input from standard 60-150mV measuring
shunt from 1ADC to 30.000ADC. The unit is used for selective current
protection of DC loads such as motors, generators etc. Relays are
differential configured.
KPM13C123E - KPM13C123F & KPM13C123GE - KPM13C123GF
DC Two Level Over Current Guard
Direct input up to 1ADC, input from standard 60-150mV measuring
shunt from 1ADC to 30.000ADC. The unit is used for selective current
protection of DC loads such as motors, generators etc. Relays are
cascade configured.
KPM13C126E - KPM13C126F & KPM13C126GE - KPM13C126GF
DC Bi-Polar Current Guard
Direct input up to 1ADC, input from standard 60-150mV measuring
shunt from 1ADC to 30.000ADC. The unit is designed for both level and
polarity of DC current to provide dual polarity excess current
protection like a charge/ discharge guard. Relays are differential
configured.
Power Controllers / Guards
KPM13M173E - KPM13M173F & KPM13M173GE - KPM13M173GF
Bi-Directional Active (kW) Power Guard
It is operating from mA output of a matching kW power transducer,
it monitors forward and reverse active load of generators. The unit has
one overload and two reverse power relay. The overload relay have
adjustable hysteresis and can be used to release and re-entry non
essential load.
KPM13M193E - KPM13M193F & KPM13M193GE - KPM13M193GF
Bi-Directional Reactive (kVAr) Power Guard
It is operating from mA output of a matching kVAr power transducer,
it monitors forward and reverse active load of generators. The unit has
one overload and two reverse power relay. The overload relay have
adjustable hysteresis and can be used to release and re-entry non
essential load.
KPM13M151E - KPM13M151F & KPM13M151GE - KPM13M151GF
AC Power Controller
It is operating on a output from the MCE105 generator controller or
from any low level DC signal i.e. 0-5V, 4-20mA etc. When used as a
"Total power" instrument it monitors the combined output of a generator
system. The relays can be used to automatically start and stop
generators in a simple system or for preferential tripping. As a
"Surplus power" instrument, it monitors the remaining available power
and therefore the relays can be used for load blocking of heavy loads.
KPM13M154E - KPM13M154F & KPM13M154GE - KPM13M154GF
AC Power Controller
It is operating on a output from balance lines from the MCE105 generator
controller or from any low level DC voltage signal i.e. 0-5V, 0-8V etc.
By monitoring the load balance lines of the MCE105, the instrument will
indicate the total percentage of power from the generators in use
regardless of the number of generators running. The trip relays can be
used to automatically start and stop generators based purely on
percentage of generated power. Scaled with 0-100%kW.
Analouge Level Controllers
KPM13M13E - KPM13M13F & KPM13M13GE - KPM13M13GF
A Low / High Universal Level Controller
It is operating from mA or volt output of any transmitter or
converter for monitoring of most physical parameters like Flow, Volume,
RPM, Vibration, Time, Pressure, Temperature, Level, Length, Weight,
Angle, RH, Dewpoint, pH, Lux, UV exposure etc. Scaled to customer
requirement. The unit has one low and one high alarm relay. The high
relay have adjustable hysteresis.
KPM13M23E - KPM13M23F & KPM13M23GE - KPM13M23GF
A two level Universal Level ControllerIt is operating from mA or volt output of any transmitter or
converter for monitoring of most physical parameters like Flow, Volume,
RPM, Vibration, Time, Pressure, Temperature, Level, Length, Weight,
Angle, RH, Dewpoint, pH, Lux, UV exposure etc. Scaled to customer
requirement. The unit has one low and one high alarm relay. The high
relay have adjustable hysteresis.