Analogue Level Controllers / Guards
KCM13M13x
A Low / High Universal Level Controller
It is operating from mA or volt output of any transmitter or
converter for monitoring of most physical parameters like Flow, Volume,
RPM, Vibration, Time, Pressure, Temperature, Level, Length, Weight,
Angle, RH, Dewpoint, pH, Lux, UV exposure etc. Scaled to customer
requirement. The unit has one low and one high alarm relay with
adjustable hysteresis.
Relay trip lamps flash instantly (approx. 1 flash per second) when
the trip level is passed, the relay trips after elapsed delay. The lamp
changes state and the trip relay operates after the pre-set delay. If a
trip condition ends during the delay interval, the timer will
automatically reset (only on Non-Latching models).
Models
KCM13M13E
KCM13M13FA
KCM13M13FB
KCM13M13G
KCM13M13GFA
KCM13M13GFB
KCM13M23x
A two level Universal Level Controller
It is operating from mA or volt output of any transmitter or
converter for monitoring of most physical parameters like Flow, Volume,
RPM, Vibration, Time, Pressure, Temperature, Level, Length, Weight,
Angle, RH, Dewpoint, pH, Lux, UV exposure etc. Scaled to customer
requirement. The unit has one low and one high alarm relay with
adjustable hysteresis.
Relay trip lamps flash instantly (approx. 1 flash per second) when the
trip level is passed, the relay trips after elapsed delay. The lamp
changes state and the trip relay operates after the pre-set delay. If a
trip condition ends during the delay interval, the timer will
automatically reset (only on Non-Latching models).
Models
KCM13M23E
KCM13M23FA
KCM13M23FB
KCM13M23G
KCM13M23GFA
KCM13M23GFB
A DC voltage guard with direct input up to 400VDC. Input from voltage
divider with grounded negative for any voltage range. The unit is used
for protection of any DC motor or mains.
Relay trip lamps flash instantly (approx. 1 flash per second) when
the trip level is passed, the relay trips after elapsed delay. The lamp
changes state and the trip relay operates after the pre-set delay. If a
trip condition ends during the delay interval, the timer will
automatically reset (only on Non-Latching models).
Models
KCM13V15E
KCM13V15FA
KCM13V15FB
KCM13V15G
KCM13V15GFA
KCM13V15GFB
Direct input up to 1ADC, input from standard 60-150mV measuring
shunt from 1ADC to 30.000ADC. The unit is used for selective current
protection of DC loads such as motors, generators etc. Relays are
differential configured.
Relay trip lamps flash instantly (approx. 1 flash per second) when
the trip level is passed, the relay trips after elapsed delay. The lamp
changes state and the trip relay operates after the pre-set delay. If a
trip condition ends during the delay interval, the timer will
automatically reset (only on Non-Latching models).
Models
KCM13C121E
KCM13C121FA
KCM13C121FB
KCM13C121G
KCM13C121GFA
KCM13C121GFB
KCM13C123x
DC Two Level Over Current Guard
Direct input up to 1ADC, input from standard 60-150mV measuring
shunt from 1ADC to 30.000ADC. The unit is used for selective current
protection of DC loads such as motors, generators etc. Relays are
cascade configured.
Relay trip lamps flash instantly (approx. 1 flash per second) when
the trip level is passed, the relay trips after elapsed delay. The lamp
changes state and the trip relay operates after the pre-set delay. If a
trip condition ends during the delay interval, the timer will
automatically reset (only on Non-Latching models).
Models
KCM13C123E
KCM13C123FA
KCM13C123FB
KCM13C123G
KCM13C123GFA
KCM13C123GFB
Direct input up to 1ADC, input from standard 60-150mV measuring
shunt from 1ADC to 30.000ADC. The unit is designed for both level and
polarity of DC current to provide dual polarity excess current
protection like a charge/ discharge guard. Relays are differential
configured.
Relay trip lamps flash instantly (approx. 1 flash per second) when the
trip level is passed, the relay trips after elapsed delay. The lamp
changes state and the trip relay operates after the pre-set delay. If a
trip condition ends during the delay interval, the timer will
automatically reset (only on Non-Latching models).